Condition:New Type: Light Control Box Maximum Wattage of 8-outlets controller = 4000 Watts when 120 Volt Input Maximum Wattage of 8-outlets controller = 8000 Watts when 240 Volt Input Maximum Amperage of 8-outlets controller = 50 Amps Hertz = 60Hz Storage Temperature = 32°F (0°C) to 135°F (57°C) Operating Temperature = 40°F (5°C) to 125°F (52°C) Installation Instructions:Not included Brand: Unbranded Product function description: NOTE: Installation Manual Is NOT Included Professional Installation Is Highly Recommended Description: The controller is specifically designed for operation of HID lighting systems. The controller will run your lights for any sequence over a 24hour period by using either and optional premium manufactured analog timer and 120 Volt relay activation cord set.8 Outlet HID hydroponic Master Light Controller Electric Box 120v /240v 50A SALE
Condition:New
Type: Light Control Box
Maximum Wattage of 8-outlets controller = 4000 Watts when 120 Volt Input
Maximum Wattage of 8-outlets controller = 8000 Watts when 240 Volt Input
Maximum Amperage of 8-outlets controller = 50 Amps
Hertz = 60Hz
Storage Temperature = 32°F (0°C) to 135°F (57°C)
Operating Temperature = 40°F (5°C) to 125°F (52°C)
Installation Instructions:Not included
Brand: Unbranded
Product function description:
NOTE:
Installation Manual Is NOT Included
Professional Installation Is Highly Recommended
D
escription:
The controller is specifically designed for operation of HID lighting systems. The controller will run your lights for any sequence over a 24hour period by using either and optional premium manufactured analog timer and 120 Volt relay activation cord set. 8-outlets controller can handle up to a maximum of eight 1000watt HID grow light. There are two 120volt accessory outlet located on the front of the controller. The “timed output” outlet is only active when your lights are “ON” and may be used to power device up to 50 amps, such as an inline fan or a pump.
Instructions for Operation :
※ THIS CONTROLLER SHOULD BE WIRED ONLY BY A LICENSED ELECTRICIAN
※ DO NOT PLUG IN POWER CORD UNTIL ALL WIRES ARE CONNECTED TO TERMINALS AND COVER PLATE INSTALLED
EXAMPLE ONE:
Connecting the 240 volt power
Connect the L1 and L2 terminals to the different hot legs, and the N terminal to neutral wire, the ↓ terminal to ground wire.
The output voltage of the outlet on both sides of controller is 240 volt.
EXAMPLE TWO:
Connecting the 120 volt power
Connect the L1 terminals to hot leg, and the L2 and N terminal to neutral wire after short-circuited by linked with a terminal bar, the ↓ terminal to ground wire.
The output voltage of the outlet on both sides of controller is 120 volt
• Please consult with a licensed electrician prior to installation of the controller
• DO NOT install this controller yourself if you DO NOT fully understand these instructions. High voltage is dangerous!
• Securely mount your controller near your enclosure and ballasts but away from any spray/water/mist, etc.
• Verify that all your wiring connections are tight and that no loose wires are exposed.
• Plug your lights into the outlets on the right and left side of the controller. • adjust the analog timer to the current time of day.
• Set your timing pattern by pushing the “time trippers” towards the center of timer.
• Make sure that all wires and cables have been properly secured.
• Turn on the power switch to activate your light bank. When the relay is activated you will hear a “Clunk” sound.
• Your controller will now control your lights at the desired settings until the power is defeated.
CAUTION: Lamps are hot and should be allowed to cool completely (approximately 15 minutes) before handling.
Controller Specifications:
• Size = 10”H x 11”W x 4”D
• Weight of 8-outlets controller = 9 lbs.
• Voltage Input = 120/240 VAC
• Voltage Output = 120/240 VAC
• Relay Coil Voltage = 120 Volts
• Maximum Amperage of 8-outlets controller = 50 Amps
Troubleshooting Tips
:
If the controller is not performing as expected, try the following:
A. Confirm that your power input is active from your breaker panel and providing 120Volts/240 Volts/ 60 Hz to the controller.
B. Check the voltage input of your incoming cord set using a voltage test meter to verify power is flowing to the controller.
C. Make sure all of your connections are tight. Loose connections can cause “arcing”.
D. Then confirm that power is active and proper at your 120Voltd/240 volt outlets.
E. Verify that your power cords and ballasts are functioning properly and that there are no shorts or arching occurring.
F. Should you find your circuit breaker keeps tripping, check your breakers to verify that they are the right amperage for your application.
G. If you turned “OFF” the power switch and your lights remain on, contact us immediately for resolution.
H. Still having problems with your controller? Please contact our to assist you further
Package includes:
· 1 X Light Control Box(Does not come with any Power Cord)